1.
Sci Rep ; 14(1): 8371, 2024 04 10.
Article in English | MEDLINE | ID: mdl-38600217

ABSTRACT

Cardiac resynchronisation therapy (CRT) improves prognosis in patients with heart failure (HF) however the role of ABO blood groups and Rhesus factor are poorly understood. We hypothesise that blood groups may influence clinical and survival outcomes in HF patients undergoing CRT. A total of 499 patients with HF who fulfilled the criteria for CRT implantation were included. Primary outcome of all-cause mortality and/or heart transplant/left ventricular assist device was assessed over a median follow-up of 4.6 years (IQR 2.3-7.5). Online repositories were searched to provide biological context to the identified associations. Patients were divided into blood (O, A, B, and AB) and Rhesus factor (Rh-positive and Rh-negative) groups. Mean patient age was 66.4 ± 12.8 years with a left ventricular ejection fraction of 29 ± 11%. There were no baseline differences in age, gender, and cardioprotective medication. In a Cox proportional hazard multivariate model, only Rh-negative blood group was associated with a significant survival benefit (HR 0.68 [0.47-0.98], p = 0.040). No association was observed for the ABO blood group (HR 0.97 [0.76-1.23], p = 0.778). No significant interaction was observed with prevention, disease aetiology, and presence of defibrillator. Rhesus-related genes were associated with erythrocyte and platelet function, and cholesterol and glycated haemoglobin levels. Four drugs under development targeting RHD were identified (Rozrolimupab, Roledumab, Atorolimumab, and Morolimumab). Rhesus blood type was associated with better survival in HF patients with CRT. Further research into Rhesus-associated pathways and related drugs, namely whether there is a cardiac signal, is required.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Middle Aged , Aged , Stroke Volume , Ventricular Function, Left , Cardiac Resynchronization Therapy/adverse effects , ABO Blood-Group System , Treatment Outcome
2.
Circ Arrhythm Electrophysiol ; 17(3): e012446, 2024 03.
Article in English | MEDLINE | ID: mdl-38258308

ABSTRACT

BACKGROUND: Antimicrobial envelopes reduce the incidence of cardiac implantable electronic device infections, but their cost restricts routine use in the United Kingdom. Risk scoring could help to identify which patients would most benefit from this technology. METHODS: A novel risk score (BLISTER [Blood results, Long procedure time, Immunosuppressed, Sixty years old (or younger), Type of procedure, Early re-intervention, Repeat procedure]) was derived from multivariate analysis of factors associated with cardiac implantable electronic device infection. Diagnostic utility was assessed against the existing PADIT score (Prior procedure, Age, Depressed renal function, Immunocompromised, Type of procedure) in both standard and high-risk external validation cohorts, and cost-utility models examined different BLISTER and PADIT score thresholds for TYRX (Medtronic; Minneapolis, MN) antimicrobial envelope allocation. RESULTS: In a derivation cohort (n=7383), cardiac implantable electronic device infection occurred in 59 individuals within 12 months of a procedure (event rate, 0.8%). In addition to the PADIT score constituents, lead extraction (hazard ratio, 3.3 [95% CI, 1.9-6.1]; P<0.0001), C-reactive protein >50 mg/L (hazard ratio, 3.0 [95% CI, 1.4-6.4]; P=0.005), reintervention within 2 years (hazard ratio, 10.1 [95% CI, 5.6-17.9]; P<0.0001), and top-quartile procedure duration (hazard ratio, 2.6 [95% CI, 1.6-4.1]; P=0.001) were independent predictors of infection. The BLISTER score demonstrated superior discriminative performance versus PADIT in the standard risk (n=2854, event rate: 0.8%, area under the curve, 0.82 versus 0.71; P=0.001) and high-risk validation cohorts (n=1961, event rate: 2.0%, area under the curve, 0.77 versus 0.69; P=0.001), and in all patients (n=12 198, event rate: 1%, area under the curve, 0.8 versus 0.75, P=0.002). In decision-analytic modeling, the optimum scenario assigned antimicrobial envelopes to patients with BLISTER scores ≥6 (10.8%), delivering a significant reduction in infections (relative risk reduction, 30%; P=0.036) within the National Institute for Health and Care Excellence cost-utility thresholds (incremental cost-effectiveness ratio, £18 446). CONCLUSIONS: The BLISTER score (https://qxmd.com/calculate/calculator_876/the-blister-score-for-cied-infection) was a valid predictor of cardiac implantable electronic device infection, and could facilitate cost-effective antimicrobial envelope allocation to high-risk patients.


Subject(s)
Anti-Infective Agents , Defibrillators, Implantable , Heart Diseases , Pacemaker, Artificial , Prosthesis-Related Infections , Humans , Middle Aged , Defibrillators, Implantable/adverse effects , Heart Diseases/complications , Anti-Bacterial Agents/therapeutic use , Risk Factors , Electronics , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/prevention & control , Pacemaker, Artificial/adverse effects
3.
JACC Clin Electrophysiol ; 10(1): 121-132, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37897463

ABSTRACT

BACKGROUND: There is a paucity of data comparing vitamin K antagonists (VKAs) to direct oral anticoagulants (DOACs) at the time of cardiac implantable electronic device (CIED) surgery. Furthermore, the best management of DOACs (interruption vs continuation) is yet to be determined. OBJECTIVES: This study aimed to compare the incidence of device-related bleeds and thrombotic events based on anticoagulant type (DOAC vs VKA) and regimen (interrupted vs uninterrupted). METHODS: This was an observational multicenter study. We included patients on chronic oral anticoagulation undergoing CIED surgery. Patients were matched using propensity scoring. RESULTS: We included 1,975 patients (age 73.8 ± 12.4 years). Among 1,326 patients on DOAC, this was interrupted presurgery in 78.2% (n = 1,039) and continued in 21.8% (n = 287). There were 649 patients on continued VKA. The matched population included 861 patients. The rate of any major bleeding was higher with continued DOAC (5.2%) compared to interrupted DOAC (1.7%) and continued VKA (2.1%) (P = 0.03). The rate of perioperative thromboembolism was 1.4% with interrupted DOAC, whereas no thromboembolic events occurred with DOAC or VKA continuation (P = 0.04). The use of dual antiplatelet therapy, DOAC continuation, and male sex were independent predictors of major bleeding on a multivariable analysis. CONCLUSIONS: In this large real-world cohort, a continued DOAC strategy was associated with a higher bleeding risk compared to DOAC interruption or VKA continuation in patients undergoing CIED surgery. However, DOAC interruption was associated with increased thromboembolic risk. Concomitant dual antiplatelet therapy should be avoided whenever clinically possible. A bespoke approach is necessary, with a strategy of minimal DOAC interruption likely to represent the best compromise.


Subject(s)
Platelet Aggregation Inhibitors , Thromboembolism , Aged , Aged, 80 and over , Humans , Male , Middle Aged , Anticoagulants/adverse effects , Fibrinolytic Agents , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Thromboembolism/epidemiology , Thromboembolism/prevention & control , Thromboembolism/etiology , Vitamin K , Female
4.
Heart Rhythm ; 21(3): 303-312, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38048935

ABSTRACT

BACKGROUND: Remote monitoring (RM) of implantable cardiac devices provides substantial and complex information, presenting new challenges such as detection of a patient's death. OBJECTIVE: This study aims to describe RM transmissions indicating death and propose a management strategy for services. METHODS: The study included consecutive ambulatory outpatients whose deaths were detected via RM. Clinical and device data were collected from electronic records, and ethical approval was obtained from the service's institutional review board. RESULTS: Over a 9-year period (2014-2023), 28 patients were detected. The deceased patients had implantable cardioverter-defibrillators, pacemakers, and implantable loop recorders. In 54% of the cases, the patient's death had already been recognized. Alert transmissions indicating death were commonly related to ventricular arrhythmia events, but also due to lead measurements, and implantable loop recorder battery status. Several diagnostic features may indicate a patient's death. The most reliable was the presenting electrogram, demonstrating base rate pacing with no capture. Device diagnostics, lead parameters, and arrhythmia recordings may indicate death; however, not all cases present with recordings and diagnosis may not be conclusive. A majority (82%) had ventricular arrhythmia at the time of death. In cases where defibrillator shocks were delivered, the arrhythmia reinitiated shortly after successful cardioversion. Delayed therapy was observed, and some patients did not receive defibrillator shocks because of discriminators or because the arrhythmia rate fell below the shock zone. CONCLUSION: Detecting a patient death via RM presents unique challenges and considerations for services. Standard operational policies and legal consultation should be established to address the implications.


Subject(s)
Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Electric Countershock/adverse effects , Monitoring, Physiologic , Heart
6.
Heart Rhythm O2 ; 4(10): 609-617, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37936670

ABSTRACT

Background: Mechanisms sustaining persistent atrial fibrillation (AF) remain unclear. Objectives: The study sought to evaluate both the clinical outcomes and response to ablation of potential drivers in patients with recurrent persistent AF recurrence following pulmonary vein isolation (PVI). Methods: A total of 100 patients with persistent AF of <2 years' duration underwent cryoballoon PVI (ECGI phenotyping of persistent AF based on driver burden and distribution to predict response to pulmonary vein isolation). Patients with documented recurrence of atrial arrhythmia within 12 months were recruited and underwent repeat PVI (if needed) followed by ablation of potential drivers (PDs) identified by electrocardiographic imaging (ECGI). PDs were defined as rotational activity >1.5 revolutions or focal activations. Cycle lengths were measured pre- and postablation. The primary outcome was freedom from atrial arrhythmia off antiarrhythmic drugs at 1 year as per guidelines. Results: Of 37 patients recruited, 26 had recurrent AF and underwent ECGI-guided ablation of PDs. An average of 6.4 ± 2.7 PDs were targeted per patient. The mean ablation time targeting PDs was 15.5 ± 6.9 minutes. An ablation response occurred in 20 patients (AF termination in 6, cycle length prolongation ≥10% in 14). At 1 year, 14 (54%) of 26 patients were free from arrhythmia, and 12 (46%) of 26 were off antiarrhythmic drugs. Considering the 96 patients who completed follow-up out of the original cohort of 100 patients undergoing cryoablation in this staged strategy, freedom from arrhythmia at 1 year following the last procedure was 72 (75%) of 96, or 70 (73%) of 96 off antiarrhythmic drugs. Conclusions: In patients with recurrent AF despite PVI, ECGI-guided ablation caused an acute response in a majority with reasonable long-term outcomes.

7.
Eur Heart J Case Rep ; 7(9): ytad411, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37743895

ABSTRACT

Background: Coronary compromise is a serious potential complication following catheter ablation; however, procedural details in the literature are often lacking, preventing the identification of learning opportunities. Case summary: We report two cases of right coronary compromise following catheter ablation for symptomatic supraventricular tachycardia. After radiofrequency energy delivery at the coronary sinus ostium in both cases, inferior lead ST-elevation was observed. Diagnostic coronary angiography identified an occluded posterior left ventricular branch of the coronary artery, and optical coherence tomography demonstrated a high thrombus burden at this location. Electrocardiographic ST-segments settled with implantation of a drug-eluting stent. Discussion: Coronary compromise was likely secondary to energy delivery during catheter ablation. This case series highlights the need for electrophysiologist to understand coronary anatomy relative to anatomical landmarks, to anticipate the risk of vascular injury as physical distance from the site of ablation is likely important. Risk for coronary compromise, while a rare complication, needs to be discussed with patients during the consenting process. We also demonstrate the importance of an efficient multi-disciplinary team process for managing acute procedural complications.

8.
Heart Rhythm ; 20(12): 1606-1614, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37633429

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is common in patients with hypertrophic cardiomyopathy (HCM) and can be challenging to manage. Atrioventricular nodal (AVN) ablation may be an effective management strategy for AF in these patients. OBJECTIVE: The purpose of this study was to assess the efficacy of AVN ablation in HCM patients who have failed medical therapy and/or catheter ablation for AF. METHODS: A multicenter study with retrospective analysis of a prospectively collated HCM registry was performed. AVN ablation patients were identified. Baseline characteristics and device and procedural indications were collected. Symptoms defined by New York Heart Association and European Heart Rhythm Association classification and echocardiographic findings during follow-up were assessed. RESULTS: Fifty-nine patients were included in the study. Indications for AVN ablation were 6 (10.2%) inappropriate implantable cardioverter-defibrillator shock, 35 (59.3%) ineffective rate control, and 18 (30.5%) to regularize rhythm for symptom improvement. During post-AVN ablation follow-up of 79.4 ± 61.1 months, left ventricular ejection fraction (LVEF) remained stable (pre-LVEF 48.9% ± 12.6% vs post-LVEF 50.1% ± 10.1%; P = .29), even in those without a cardiac resynchronization therapy (CRT) device (pre-LVEF 54.3% ± 8.0% vs post-LVEF 53.8% ± 8.0%; P = .65). Forty-nine patients (83.1%) reported an improvement in symptoms regardless of AF type (17/21 [81.0%] paroxysmal vs 32/38 [84.2%] persistent; P = 1.00), presence of baseline left ventricular impairment (22/26 [84.6%] LVEF ≤50% vs 27/33 [81.8%] LVEF ≥50%; P = 1.00) or CRT device (27/32 [84.4%] CRT vs 22/27 [81.5%] no CRT; P = 1.00). Symptoms improved in 16 patients (89.0%) who underwent AVN ablation to regularize rhythm. CONCLUSION: AVN ablation improved symptoms without impacting left ventricular function in the majority of patients. The data suggest that AVN ablation is an effective and safe management approach for AF in HCM and should be further evaluated in larger prospective studies.


Subject(s)
Atrial Fibrillation , Cardiomyopathy, Hypertrophic , Catheter Ablation , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrioventricular Node/surgery , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnosis , Cardiomyopathy, Hypertrophic/therapy , Prospective Studies , Retrospective Studies , Stroke Volume , Treatment Outcome , Ventricular Function, Left
9.
Front Cardiovasc Med ; 10: 1110165, 2023.
Article in English | MEDLINE | ID: mdl-37051067

ABSTRACT

Introduction: Outcomes of catheter ablation for non-paroxysmal atrial fibrillation (AF) remain suboptimal. Non-invasive stratification of patients based on the presence of atrial cardiomyopathy (ACM) could allow to identify the best responders to pulmonary vein isolation (PVI). Methods: Observational multicentre retrospective study in patients undergoing cryoballoon-PVI for non-paroxysmal AF. The duration of amplified P-wave (APW) was measured from a digitally recorded 12-lead electrocardiogram during the procedure. If patients were in AF, direct-current cardioversion was performed to allow APW measurement in sinus rhythm. An APW cut-off of 150 ms was used to identify patients with significant ACM. We assessed freedom from arrhythmia recurrence at long-term follow-up in patients with APW ≥ 150 ms vs. APW < 150 ms. Results: We included 295 patients (mean age 62.3 ± 10.6), of whom 193 (65.4%) suffered from persistent AF and the remaining 102 (34.6%) from long-standing persistent AF. One-hundred-forty-two patients (50.2%) experienced arrhythmia recurrence during a mean follow-up of 793 ± 604 days. Patients with APW ≥ 150 ms had a significantly higher recurrence rate post ablation compared to those with APW < 150 ms (57.0% vs. 41.6%; log-rank p < 0.001). On a multivariable Cox-regression analysis, APW≥150 ms was the only independent predictor of arrhythmia recurrence post ablation (HR 2.03 CI95% 1.28-3.21; p = 0.002). Conclusion: APW duration predicts arrhythmia recurrence post cryoballoon-PVI in persistent and long-standing persistent AF. An APW cut-off of 150 ms allows to identify patients with significant ACM who have worse outcomes post PVI. Analysis of APW represents an easy, non-invasive and highly reproducible diagnostic tool which allows to identify patients who are the most likely to benefit from PVI-only approach.

10.
Eur J Heart Fail ; 25(1): 77-86, 2023 01.
Article in English | MEDLINE | ID: mdl-36221809

ABSTRACT

AIMS: The ARC-HF and CAMTAF trials randomized patients with persistent atrial fibrillation (AF) and heart failure (HF) to early routine catheter ablation (ER-CA) versus pharmacological rate control (RC). After trial completion, delayed selective catheter ablation (DS-CA) was performed where clinically indicated in the RC group. We hypothesized that ER-CA would result in a lower risk of cardiovascular hospitalization and death versus DS-CA in this population. METHODS AND RESULTS: Overall, 102 patients were randomized (age 60 ± 11 years, left ventricular ejection fraction [LVEF] 31 ± 11%): 52 to ER-CA and 50 to RC. After 12 months, patients undergoing ER-CA had improved self-reported symptom scores, lower New York Heart Association class (i.e. better functional capacity), and higher LVEF compared to patients receiving RC alone. During a median follow-up of 7.8 (interquartile range 3.9-9.9) years, 27 (54%) patients in the RC group underwent DS-CA and 34 (33.3%) patients died, including 17 (32.7%) randomized to ER-CA and 17 (34.0%) randomized to RC. Compared with DS-CA, a strategy of ER-CA exhibited similar risk of all-cause mortality (adjusted hazard ratio [aHR] 0.89, 95% confidence interval [CI] 0.44-1.77, p = 0.731) and combined all-cause mortality or cardiovascular hospitalization (aHR 0.80, 95% CI 0.43-1.47, p = 0.467). However, analyses according to treatment received suggested an association between CA and improved outcomes versus RC (all-cause mortality: aHR 0.43, 95% CI 0.20-0.91, p = 0.028; all-cause mortality/cardiovascular hospitalization: aHR 0.48, 95% CI 0.24-0.94, p = 0.031). CONCLUSIONS: In patients with persistent AF and HF, ER-CA produces similar long-term outcomes to a DS-CA strategy. The association between CA as a treatment received and improved outcomes means there is still a lack of clarity regarding the role of early CA in selected patients. Randomized trials are needed to clarify this question.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Failure , Ventricular Dysfunction, Left , Humans , Middle Aged , Aged , Atrial Fibrillation/complications , Atrial Fibrillation/surgery , Stroke Volume , Ventricular Function, Left , Treatment Outcome , Anti-Arrhythmia Agents/therapeutic use , Ventricular Dysfunction, Left/drug therapy , Catheter Ablation/methods
11.
Europace ; 25(2): 536-545, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36480445

ABSTRACT

AIMS: Cardiac resynchronization therapy programmed to dynamically fuse pacing with intrinsic conduction using atrioventricular (AV) timing algorithms (e.g. SyncAV) has shown promise; however, mechanistic data are lacking. This study assessed the impact of SyncAV on electrical dyssynchrony across various pacing modalities using non-invasive epicardial electrocardiographic imaging (ECGi). METHODS AND RESULTS: Twenty-five patients with left bundle-branch block (median QRS duration (QRSd) 162.7 ms) and intact AV conduction (PR interval 174.0 ms) were prospectively enrolled. ECGi was performed acutely during biventricular pacing with fixed nominal AV delays (BiV) and using SyncAV (optimized for the narrowest QRSd) during: BiV + SyncAV, LV-only single-site (LVSS + SyncAV), MultiPoint pacing (MPP + SyncAV), and LV-only MPP (LVMPP + SyncAV). Dyssynchrony was quantified via ECGi (LV activation time, LVAT; RV activation time, RVAT; LV electrical dispersion index, LVEDi; ventricular electrical uncoupling index, VEU; and biventricular total activation time, VVtat). Intrinsic conduction LVAT (124 ms) was significantly reduced by BiV pacing (109 ms) (P = 0.001) and further reduced by LVSS + SyncAV (103 ms), BiV + SyncAV (103 ms), LVMPP + SyncAV (95 ms), and MPP + SyncAV (90 ms). Intrinsic RVAT (93 ms), VVtat (130 ms), LVEDi (36 ms), VEU (50 ms), and QRSd (163 ms) were reduced by SyncAV across all pacing modes. More patients exhibited minimal LVAT, VVtat, LVEDi, and QRSd with MPP + SyncAV than any other modality. CONCLUSION: Dynamic AV delay programming targeting fusion with intrinsic conduction significantly reduced dyssynchrony, as quantified by ECGi and QRSd for all evaluated pacing modes. MPP + SyncAV achieved the greatest synchrony overall but not for all patients, highlighting the value of pacing mode individualization during fusion optimization.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Bundle-Branch Block/diagnostic imaging , Bundle-Branch Block/therapy , Heart Failure/therapy , Cardiac Resynchronization Therapy/methods , Electrocardiography , Cardiac Resynchronization Therapy Devices , Treatment Outcome
12.
Arrhythm Electrophysiol Rev ; 11: e19, 2022 Apr.
Article in English | MEDLINE | ID: mdl-36304202

ABSTRACT

Pacemakers are a key technology in the treatment of bradyarrhythmias. Leadless pacemakers (LP) were introduced to address limitations of transvenous devices. However, guidelines and other restrictions have led to LPs becoming niche products. The aim of this consensus statement was to determine the strength of opinion of UK implantation experts as to how LPs can be more optimally used. Using a modified Delphi approach, a panel of LP experts developed 36 statements that were used to form a survey that was distributed to LP implanters in the UK. Stopping criteria included a 3-month window for response, a minimum 25% response rate and at least 75% of statements achieving the threshold for consensus (agreed at 66%). In all, 31 of 36 statements reached consensus, and 23 of these achieved ≥90% agreement. Five statements did not achieve consensus. On the basis of these results, seven recommendations were proposed. The implementation of these recommendations may increase the use of LPs, with the aim of improving patient outcomes.

14.
J Cardiovasc Electrophysiol ; 33(11): 2263-2273, 2022 11.
Article in English | MEDLINE | ID: mdl-35924481

ABSTRACT

BACKGROUND: This prospective trial sought to phenotype persistent atrial fibrillation (AF) based on AF mechanisms using electrocardiographic imaging (ECGI) mapping to determine whether this would predict long-term freedom from arrhythmia after pulmonary vein isolation (PVI). METHODS: Patients with persistent AF of <2 years duration underwent cryoballoon PVI. ECGI mapping was performed before PVI to determine potential drivers (PDs) defined as rotational activations completing ≥1.5 revolutions or focal activations. The coprimary endpoint was the association between (1) PD burden (defined as the number of PD occurrences) and (2) PD distribution (defined as the number of segments on an 18-segment model of the atria harboring PDs) with freedom from arrhythmia at 1-year follow up. RESULTS: Of 100 patients, 97 completed follow up and 52 (53.6%) remained in sinus rhythm off antiarrhythmic drugs. Neither PD burden nor PD distribution predicted freedom from arrhythmia (hazard ratio [HR]: 1.01, 95% confidence interval [CI]: 0.99-1.03, p = .164; and HR: 1.04, 95% CI: 0.91-1.17, p = .591, respectively). Otherwise, the burden of rotational PDs, rotational stability, and the burden of PDs occurring at the pulmonary veins and posterior wall all failed to predict arrhythmia recurrence (all p > .10). CONCLUSIONS: AF mechanisms as determined using ECGI mapping do not predict outcomes after PVI for persistent AF. Further studies using different methodologies to characterize AF mechanisms are warranted (NCT03394404).


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Prospective Studies , Recurrence , Treatment Outcome , Electrocardiography , Phenotype , Catheter Ablation/adverse effects , Catheter Ablation/methods
15.
Europace ; 24(9): 1420-1429, 2022 10 13.
Article in English | MEDLINE | ID: mdl-35737685

ABSTRACT

AIM: Evaluate the novel PolarX Cryoballoon in atrial fibrillation (AF) catheter ablation through a propensity-matched comparison with the Arctic Front Advance (AFA). The aim was also to identify cryoablation metrics that are predictive of successful pulmonary vein isolation (PVI) with the PolarX Cryoballoon. METHODS AND RESULTS: This prospective multi-centre study included patients that underwent cryoablation for AF. All patients underwent PVI with reconnection assessed after a 30-min waiting period and adenosine. Safety, efficacy, and cryoablation metrics were compared between PolarX and a propensity-matched AFA cohort. Seventy patients were included with 278 veins treated. In total, 359 cryoablations were performed (1.3 ± 0.6 per vein) to achieve initial PVI with 205 (73.7%) veins isolating with a single cryoablation. Independent predictors for achieving initial PVI included temperature at 30 s [odds ratio (OR) 1.26; P = 0.003] and time to reach -40°C (OR 1.88; P < 0.001) with an optimal cut-off of ≤-38.5°C at 30 s [area under the curve (AUC) 0.79; P < 0.001] and ≤-40°C at ≤32.5 s (AUC 0.77; P < 0.001), respectively. Of the 278 veins, 46 (16.5%) veins showed acute reconnection. Temperature at 30 s (≤-39.5°C, OR 1.24; P = 0.002), nadir temperature (≤-53.5°C, OR 1.35; P = 0.003), and time to isolation (≤38.0 s, OR 1.18; P = 0.009) were independent predictors of sustained PVI. Combining two of these three targets was associated with reconnection in only 2-5% of PVs. Efficacy and safety of the PolarX Cryoballoon were comparable to AFA Cryoballoon, however, cryoablation metrics were significantly different. CONCLUSIONS: The PolarX Cryoballoon has a different cryoablation profile to AFA Cryoballoon. Prospective testing of these proposed targets in large outcomes studies is required.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Adenosine , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Benchmarking , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cryosurgery/adverse effects , Cryosurgery/methods , Humans , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Time Factors , Treatment Outcome
16.
J Cardiovasc Electrophysiol ; 33(8): 1747-1755, 2022 08.
Article in English | MEDLINE | ID: mdl-35671359

ABSTRACT

AIMS: Cardiac tamponade is a high morbidity complication of transseptal puncture (TSP). We examined the associations of TSP-related cardiac tamponade (TRCT) for all patients undergoing left atrial ablation at our center from 2016 to 2020. METHODS AND RESULTS: Patient and procedural variables were extracted retrospectively. Cases of cardiac tamponade were scrutinized to adjudicate TSP culpability. Adjusted multivariate analysis examined predictors of TRCT. A total of 3239 consecutive TSPs were performed; cardiac tamponade occurred in 51 patients (incidence: 1.6%) and was adjudicated as TSP-related in 35 (incidence: 1.1%; 68.6% of all tamponades). Patients of above-median age [odds ratio (OR): 2.4 (1.19-4.2), p = .006] and those undergoing re-do procedures [OR: 1.95 (1.29-3.43, p = .042] were at higher risk of TRCT. Of the operator-dependent variables, choice of transseptal needle (Endrys vs. Brockenbrough, p > .1) or puncture sheath (Swartz vs. Mullins vs. Agilis vs. Vizigo vs. Cryosheath, all p > .1) did not predict TRCT. Adjusting for operator, equipment and demographics, failure to cross the septum first pass increased TRCT risk [OR: 4.42 (2.45-8.2), p = .001], whilst top quartile operator experience [OR: 0.4 (0.17-0.85), p = .002], transoesophageal echocardiogram [TOE prevalence: 26%, OR: 0.51 (0.11-0.94), p = .023], and use of the SafeSept transseptal guidewire [OR: 0.22 (0.08-0.62), p = .001] reduced TRCT risk. An increase in transseptal guidewire use over time (2016: 15.6%, 2020: 60.2%) correlated with an annual reduction in TRCT (R2 = 0.72, p < .001) and was associated with a relative risk reduction of 70%. CONCLUSIONS: During left atrial ablation, the risk of TRCT was reduced by operator experience, TOE-guidance, and use of a transseptal guidewire, and was increased by patient age, re-do procedures, and failure to cross the septum first pass.


Subject(s)
Atrial Fibrillation , Cardiac Tamponade , Catheter Ablation , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cardiac Catheterization , Cardiac Tamponade/diagnostic imaging , Cardiac Tamponade/epidemiology , Cardiac Tamponade/etiology , Catheter Ablation/methods , Humans , Punctures/adverse effects , Retrospective Studies , Risk Factors , Treatment Outcome
17.
JACC Clin Electrophysiol ; 8(4): 426-436, 2022 04.
Article in English | MEDLINE | ID: mdl-35450597

ABSTRACT

OBJECTIVES: This study sought to assess the association between electrocardiographic imaging (ECGI) parameters and voltage from simultaneous electroanatomic mapping (EAM). BACKGROUND: ECGI offers noninvasive assessment of electrophysiologic features relevant for mapping ventricular arrhythmia and its substrate, but the accuracy of ECGI in the delineation of scar is unclear. METHODS: Sixteen patients with structural heart disease underwent simultaneous ECGI (CardioInsight, Medtronic) and contact EAM (CARTO, Biosense-Webster) during ventricular tachycardia catheter ablation, with 7 mapped epicardially. ECGI and EAM geometries were coregistered using anatomic landmarks. ECGI points were paired to the closest site on the EAM within 10 mm. The association between EAM voltage and ECGI features from reconstructed epicardial unipolar electrograms was assessed by mixed-effects regression models. The classification of low-voltage regions was performed using receiver-operating characteristic analysis. RESULTS: A total of 9,541 ECGI points (median: 596; interquartile range: 377-737 across patients) were paired to an EAM site. Epicardial EAM voltage was associated with ECGI features of signal fractionation and local repolarization dispersion (N = 7; P < 0.05), but they poorly classified sites with bipolar voltage of <1.5 mV or <0.5 mV thresholds (median area under the curve across patients: 0.50-0.62). No association was found between bipolar EAM voltage and low-amplitude reconstructed epicardial unipolar electrograms or ECGI-derived bipolar electrograms. Similar results were found in the combined cohort (n = 16), including endocardial EAM voltage compared to epicardial ECGI features (n = 9). CONCLUSIONS: Despite a statistically significant association between ECGI features and EAM voltage, the accuracy of the delineation of low-voltage zones was modest. This may limit ECGI use for pr-procedural substrate analysis in ventricular tachycardia ablation, but it could provide value in risk assessment for ventricular arrhythmias.


Subject(s)
Heart Diseases , Tachycardia, Ventricular , Electrocardiography/methods , Endocardium , Epicardial Mapping/methods , Humans , Tachycardia, Ventricular/surgery
18.
Heart Rhythm ; 19(6): 875-884, 2022 06.
Article in English | MEDLINE | ID: mdl-35134548

ABSTRACT

BACKGROUND: Mechanisms sustaining persistent atrial fibrillation (AF) remain uncertain. OBJECTIVES: The purpose of this study was to use electrocardiographic imaging (ECGI) mapping to guide localized driver ablation in patients with persistent AF. METHODS: Patients undergoing catheter ablation for persistent AF <2 years were included. Patients were enrolled consecutively between 2018 and 2020. ECGI mapping was used to identify focal and rotational potential drivers (PDs). PDs were ablated after pulmonary vein isolation (PVI). The ablation response and freedom from AF/atrial tachycardia (AT) at 1 year were assessed. RESULTS: Forty patients were enrolled. AF terminated with PVI in 8 patients, and 32 underwent ECGI-guided driver ablation. Average procedural duration was 228.8 ± 66.7 minutes, with a total radiofrequency delivery time of 38.9 ± 14.1 minutes. During 1 year of follow-up, the primary endpoint of freedom from AF/AT was achieved in 26 patients (65%). The secondary endpoint of freedom from AF was achieved in 30 patients (75%). AF termination was achieved in 20 of 40 patients (50%). The composite endpoint of an ablation response (AF termination or cycle length slowing ≥10%) occurred in 37 of 40 patients (92.5%). In total, 181 drivers (48 focal and 133 rotational) were ablated, with an ablation response achieved in 59 (32.6%). Focal drivers and drivers with a higher recurrence rate and greater temporal stability were more likely to be associated with an ablation response including AF termination (P <.001). CONCLUSION: ECGI-guided ablation plus PVI results in high freedom from AF during follow-up and an ablation response in a large proportion of patients. Using driver type and characteristics may facilitate a hierarchical ablation approach.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Tachycardia, Supraventricular , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Rate/physiology , Humans , Pulmonary Veins/surgery , Recurrence , Time Factors , Treatment Outcome
19.
Pacing Clin Electrophysiol ; 45(3): 365-373, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35023176

ABSTRACT

BACKGROUND: The risk factors for developing pacing induced left ventricular dysfunction (LVD) in patients with high burden of right ventricular pacing (RVP) is poorly understood. Therefore, in the present study, we aimed to assess the determinants of pacing induced LVD. METHODS: Our data were retrospectively collected from 146 patients with RVP > 40% who underwent generator change (GC) or cardiac resynchronization therapy (CRT) upgrade between 2016 and 2019 who had left ventricular ejection fraction (EF) ≥50% at initial implant. RESULTS: A total of 75 patients had CRT upgrade due to pacing induced LVD (EF < 50%) and 71 patients with preserved LV function (EF ≥ 50%) had a GC. Primary indication for pacing in both groups was complete heart block. Male predominance (p = .008), prior myocardial infarction (MI) (p = .001), atrial fibrillation (AF) (p = .009), chronic kidney disease (CKD) (p = .005), and borderline low systolic function (BLSF) (EF 50%-55%) (p = .04) were more prevalent in the CRT upgrade group. Presence of AF (odds ratio [OR] = 3.05, 95% confidence interval [CI] 1.42-6.58; p = .004), BLSF (OR = 3.8, 95% CI 1.22-11.8; p = .02), and male gender (OR = 2.41, 95% CI 1.14-5.08; p = .02) were independent predictors for RVP induced LVD. Age (OR = 1.08, 95% CI 1.02-1.14; p = .005) and BLSF (OR = 5.33, 95% CI 1.26-22.5; p = .023) were independent predictors of earlier development of LVD after implant. CONCLUSIONS: Our results suggested that AF, BLSF, and male gender are predictors for development of pacing induced LVD in patients with high RVP burden. LVD can occur at any time after pacemaker implant with BLSF and increasing age associated with earlier development of LVD.


Subject(s)
Atrial Fibrillation , Cardiac Resynchronization Therapy , Heart Failure , Ventricular Dysfunction, Left , Atrial Fibrillation/therapy , Cardiac Pacing, Artificial/methods , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Female , Heart Failure/therapy , Humans , Male , Retrospective Studies , Risk Factors , Stroke Volume , Treatment Outcome , United Kingdom/epidemiology , Ventricular Function, Left
20.
Pacing Clin Electrophysiol ; 45(1): 103-110, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34727374

ABSTRACT

BACKGROUND: Permanent pacemaker (PPM) implantation is a common complication of transcatheter aortic valve implantation (TAVI). The optimum timing of PPM implantation is still unclear as conduction abnormalities evolve and a balance needs to be struck between conservative delays in the hope of conduction recovery and overutilization of pacing. This study aimed to assess the safety and efficacy of early PPM implantation, without an observation period, among TAVI patients. METHODS: This is a retrospective, observational study of 1398 TAVI patients. Clinical and pacing data were collected at baseline, 30 days and at a median of 15 (4-21) months post-TAVI. Study endpoints included PPM-related complications, pacing utilization and hospital length of stay. RESULTS: One hundred five patients (8.2%) required a PPM, of which 13 were implanted pre and 92 post-TAVI. Seventy-six percent required pacing for either second- or third-degree heart block. Time to implantation for post-TAVI PPM was 1 (0-3) day. Six patients experienced a pacing-related complication- lead displacement (n = 3), hematoma (n = 2), and device infection (n = 1). Pacing utilization defined as pacing >10% of the time or a pacing requirement at the time of the pacing check was demonstrated in 83% of patients. Multivariate analysis revealed complete heart block (CHB) was the only independent predictor of pacing utilization. Hospital length of stay for the post-TAVI PPM group was longer than the group without PPM (4 [2-8] vs. 3 [2-4] days; p < .001). CONCLUSIONS: Early PPM implantation in TAVI patients is safe and majority of patients require pacing in the short and mid-term.


Subject(s)
Cardiac Pacing, Artificial , Pacemaker, Artificial , Postoperative Complications/prevention & control , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Length of Stay/statistics & numerical data , Male , Retrospective Studies